Hydro Turbine Generator units & Accessories with Unit Capacity 1 00KW- 1 00MW
Type of Hydro Turbine Generator Units: Francis, Kaplan, Pelton, Turgo, Tubular, Bulb etc.
Type
Item |
Francis |
Kaplan |
Pelton, Turgo |
Tubular , Bulb |
Turbine |
|
Model |
HL |
ZD, ZZ |
CJ, XJ |
GD, GZ |
Rated head (m) |
10 - 300 m |
2 - 70 m |
80- 1600 m |
2 - 20 m |
Rated flow (m 3 /s) |
0.3 - 100 |
1.0 - 200 |
0.1 - 20 |
1.0 - 250 |
Rated speed (rpm) |
68.2 – 1500 rpm |
68.2 – 750 rpm |
150 – 1500 rpm |
75 – 500 rpm |
Rated output (KW) |
100KW-100MW |
100KW-100MW |
100KW-80MW |
200KW-60MW |
Runner Diameter (M) |
0.4 – 6.0 m |
0.8 - 8.0 m |
0.8 - 6.0 m |
0.8 – 6.0 m |
Generator |
|
Model |
SF |
SF |
SF |
SF |
Rated Capacity (KW) |
100KW-100MW |
100KW-100MW |
100KW-80MW |
200KW-60MW |
Rated output (KW) |
100KW-100MW |
100KW-100MW |
100KW-80MW |
200KW-60MW |
Rated voltage(KV) |
0.4, 6.3, 6.6, 10.5 |
0.4, 6.3, 6.6,10.5 |
0.4, 6.3, 6.6, 10.5 |
0.4, 6.3, 6.6, 10.5 |
Rated speed |
68.2-1500rpm |
68.2-750rpm |
150-1500rpm |
75-500rpm |
Sell Francis Turbine Generator Units
Francis turbines of both vertical and horizontal types are suitable for water head from 10m to 300m. lts feature is that the water flow enters the runner inward in a radial direction , changes direction gradually and then passes out axially. Francis turbine is characterized by reliable operation, simple construction and high efficiency, etc. Normally, we adopt the horizontal Francis with capacity below 5MW, runner diameter below 90cm.
Sell Kaplan Turbine Generator Units
The Kaplan (axial-flow) turbine for low head from 2m to 70m. lts feature is that the water flow passes through the runner axially. The axial-flow turbine can be classified into two forms according to the runner construction: one is fixed blades (Propeller) for small variation of head and power, the other is movable blades (Kaplan) for large variation of head and power.
Sell Tubular and Bulb Turbine Generator Units
Tubular turbine and Bulb turbine is suitable for heads from 2m to 20m and large discharge. lts feature is that the water flow is axial throughout the passage from the inlet to the outlet, so that the passage is a straight conduit essentially. The tubular turbine is characterized by good characteristic of water flow and high efficiency etc.
Sell Pelton Turbine Generator Units
The Pelton hydraulic turbine is suitable for heads fron 80-1600m. lt utilizes the dynamic power of water flow to rotate the runner and do work, The centre line of the jet is in the same plane as the runner. Pelton turbine has the advantages of compact construction, stable running and easy operation.
Sell Excitation Systems
|
Static Silicon Control Excitation system for low-voltage generator
Generator voltage: 0.4KV
Regulator is mainly controlled by integrated circuit/microcomputer
Regulatin method is AVR. Model of microcomputer regulator can run with constant
voltage, constant current and constant power factor.
Static Silicon Control Excitation system for high-voltage small capacity generator
Generator voltage: 6.3KV , 6.6KV
The primary loop adopts two-phase half-controlled or three-phase all-controlled
Residual voltage self-excitation, separated excitation and manual excitation.
Regulator can run constant voltage, constant current and constant power factor way.
Multiple fault monitor.
Automatic tracking of system voltage in interconnection guarantees quick
synchronization
Static Silicon Control Excitation system for medium/large turbine generator units
Generator voltage: 6.3KV , 6.6KV, 10.5KV
Generator capacity: 10MW- 100MW
The regulator adopts 32 bit industrial MCU microcomputer + DSP controller as
measuring control core
It has functions: AC sampling, test and fault record; working condition intelligent
detection, intelligent digital transmission, intelligent fan control, intelligent
power cabinet, intelligent power cabinet withdrawal, intelligent current
equalization of power cabinet etc.
It supports network communication interfaces including I/O, field – bus such as
CANBUS, RS485 and Ethernet and English/Chinese display/operation interface.
|
Sell Inlet Valves
Motor-Driving/Manual control Butterfly Valve
Nominal Diameter: 50 – 3000 mm
Nominal Pressure: 0.25 - 2.5 Mpa
Hydraulic control (Heavy Hammer type) Butterfly Valve
Nominal Diameter: 300 – 5000 mm
Nominal Pressure: 0.25 - 2.5 Mpa
Motor-Driving/Manual control Gate Valve
Nominal Diameter: 50 – 1600 mm
Nominal Pressure: 0.25 – 4.0 Mpa
Motor-Driving/Manual control Globe Valve
Nominal Diameter: 50 – 1000 mm
Nominal Pressure: 0.6 – 10.0 Mpa
Hydraulic control (Heavy Hammer type) Globe Valve
Nominal Diameter: 300 – 2600 mm
Nominal Pressure: 1.6 – 16.0 Mpa
Sell Governors
|
PLC governor for small turbine generator units
|
Capacity: 3,000 –15,000 Nm
Power supply: AC380V, 220V
DC220V, 110V
Operating oil pressure: 2.5/4.0Mpa
Range of adjustment for opening/closing time: 2.5 - 40s
PID Regulator Parameter Setting Range:
Proportional gain Kp: 0.5 - 20
Integral Gain KI: 0.05 - 10 l/s
Derivative KD: 0 - 10s
Permanent speed droop: 0 - 10%
 |
PLC governor for Pelton turbine generator unit
|
Capacity: 3,000 –75,000 Nm
Power supply: AC380V, 220V
DC220V, 110V
Operating oil pressure: 2.5/4.0Mpa
Range of adjustment for opening/closing time: 2.5 - 40s
PID Regulator Parameter Setting Range:
Proportional gain Kp: 0.5 - 20
Integral Gain KI: 0.05 - 10 l/s
Derivative KD: 0 - 10s
Permanent speed droop: 0 - 10%
 |
PLC governor for medium turbine generator unit
|
Capacity: 18,000 –75,000 Nm
Power supply: AC380V, 220V
DC220V, 110V
Operating oil pressure: 2.5/4.0/6.3Mpa
Range of adjustment for opening/closing time: 6 - 40s
PID Regulator Parameter Setting Range:
Proportional gain Kp: 0.5 - 20
Integral Gain KI: 0.05 - 10 l/s
Derivative KD: 0 - 10s
Permanent speed droop: 0 - 10%
 |
PLC governor for large turbine generator unit
|
Capacity(Servomotor Dia.): 50/80/100/150/200/250mm
Power supply: AC380V, 220V
DC220V, 110V
Operating oil pressure: 2.5/4.0/6.3/16.0 Mpa
Range of adjustment for opening/closing time: 6 - 40s
PID Regulator Parameter Setting Range:
Proportional gain Kp: 0.5 - 20
Integral Gain KI: 0.05 - 10 l/s
Derivative KD: 0 - 10s
Permanent speed droop: 0 - 10%

|
|
Sell Oil, Water, Air System of Hydropower Plant
Sell Control System & SCADA system
|
PLC CONTROLLER
The SCADA system would provide the hydro station with one programmable logic
controller (PLC) along with operator station with LCD/CRT and printer for executing the
- Sequential start/stop functions
- Monitoring and control functions
- Event recording
- Generation of information
ACTION
PLC shall ensure the sequential start/stop of
- Turbine generator units
- Unit auxiliaries
- Common auxiliaries
- Butterfly valves
INFORMATION
PLC shall scan the digital inputs from contacts and analog inputs from transducers.
It shall perform the function of data acquisition, pre-processing and time lagging for
status, alarms, and measurements. It shall generate periodic information report as
desired at the adjustable time intervals.
LCD/CRT DISPLAYS
a Display of alarms:
Alarms shall be displayed in chronological order with time of occurrence and
description in plain text with color related to evel of urgency. Operator shall have
the facility to consult and acknowledge the last alarm events or the list of adjustable
alarms. Alarm shall be scanned and printed with 10 millisecond revolution.
b History of events
The events, which are logged on the printer, shall also be stored on hour, day, week,
and month basis for later consultation of CRT.
c History of measurements
The measurements shall also be stored in same way as events for later consultation
of LCD /CRT in the form of a table.
d Mimic diagrams
The plant mimic diagrams shall be provided in the form of displays. The number of
mimics shall be a minimum of 5 numbers.
e Printer logs and other information
|
Sell AC Power Distribution System
|
AC power house service transformer

AC power distribution panel

|
Sell DC Power Supply Source
|
DC power supply source:
DC voltage: 24V, 48V, 110V, 220V
Capacity: 40AH, 100AH, 200AH, 400AH, 800AH

|
Sell Indoor Switch Cubicles
Sell Main Step-up Transformers
|
New S9 11KV step up main transformer
Capacity: 50 –1,600KVA

36KV step up main transformer
Capacity: 50 –16,000KVA

110KV step up main transformer
Capacity: 6,300 – 63,000KVA

220KV step up main transformer
Capacity: 6,300 – 63,000KVA

|
Sell Sub-station Equipment
Sell Auxiliaries for Hydropower plant
|